INV=NOT_INVERTED, PULSE=DISABLE_SINGLE_PULSE, SYNCH=DISABLE__SYNCHRONIZ, EDGE=NO_EDGE_DETECTION, SELECT=CTOUT_15_OR_T3_MAT3
Timer 0 CAP0_3 capture input multiplexer (GIMA output 3)
INV | Invert input 0 (NOT_INVERTED): Not inverted. 1 (INPUT_INVERTED): Input inverted. |
EDGE | Enable rising edge detection 0 (NO_EDGE_DETECTION): No edge detection. 1 (RISING_EDGE_DETECTIO): Rising edge detection enabled. |
SYNCH | Enable synchronization 0 (DISABLE__SYNCHRONIZ): Disable synchronization. 1 (ENABLE__SYNCHRONIZA): Enable synchronization. |
PULSE | Enable single pulse generation. 0 (DISABLE_SINGLE_PULSE): Disable single pulse generation. 1 (ENABLE_SINGLE_PULSE): Enable single pulse generation. |
SELECT | Select input. Values 0x3 to 0xF are reserved. 0 (CTOUT_15_OR_T3_MAT3): CTOUT_15 or T3_MAT3 1 (T0_CAP3): T0_CAP3 2 (T3_MAT3): T3_MAT3 |
RESERVED | Reserved |